Chapter 4 - AT Commands, S-Registers, Result Codes

18

MultiModemDID User Guide

Command:

&D

n Data Terminal Ready (DTR) Control

Values:

n = 0, 1, 2, or 3

Default:

2

Description:

&D0

Modem ignores the true status of the DTR signal and responds

as if it is always on.

&D1

If DTR drops while in online data mode, the modem enters
command mode, issues an

OK, and remains connected.

&D2

If DTR drops while in online data mode, the modem hangs up.
If the signal is not present, the modem will not answer or dial.

&D3

If DTR drops, the modem hangs up and resets as if an ATZ
command were issued.

Command:

&E

n

XON/XOFF Pacing Control

Values:

n = 12 or 13

Default:

12

Description:

&E12 Disables XON/XOFF pacing.
&E13 Enables XON/XOFF pacing. (&K4 must also be set.)

Note: &E13 has no effect if hardware control (&K3) is selected.

Command:

&F

n

Load Factory Settings

Values:

n = 0

Default:

None

Description:

&F0

Loads factory settings as active configuration.

Note: See also the Z

command.

Command:

&G

n V.22bis Guard Tone Control

Values:

n = 0, 1, or 2

Default:

0

Description:

&G0

Disables guard tone.

&G1

Sets guard tone to 550 Hz.

&G2

Sets guard tone to 1800 Hz.

Note: The

&G command is not used in North America.

Command:

&K

n Flow Control Selection

Values:

n = 0, 3, or 4

Defaults:

3

Description:

&K0

Disables flow control.

&K3

Enables CTS/RTS hardware flow control.

&K4

Enables XON/XOFF software flow control.

Command:

&Q

n Asynchronous Communications Mode

Values:

n = 0, 5, 6, 8, or 9

Default:

5

Description:

&Q0

Asynchronous with data buffering. Same as \N0.

&Q5

Error control with data buffering. Same as \N3.

&Q6

Asynchronous with data buffering. Same as \N0.

&Q8

MNP error control mode. If MNP error control is not
established, the modem falls back according to the setting in
S36.

&Q9

V.42 or MNP error control mode. If neither error control is
established, the modem falls back according to the setting in
S36.

Advertising