Chapter 4 - AT Commands, S-Registers, Result Codes

23

MultiModemDID User Guide

Command:

%R

n Cisco Configuration

Values:

n = 0, 1

Default:

0

Description:

%R0 Disables Cisco configuration.
%R1 Sets E0, Q1, &D0, \N0, $SB9600, and %S1 for operation with

a Cisco router.

Command:

%S

n Command Speed Response

Values:

n = 0, 1

Default:

0

Description:

%S0 Sets modem to respond to AT commands at all normal speeds.

%S1 AT commands accepted at 115200 bps only. AT commands at

other speeds are ignored.

Command:

$D

n

DTR Dialing

Values:

n = 0 or 1

Default:

0

Description:

$D0

Disables DTR dialing.

$D1

Dials the number in memory location 0 when DTR goes high.

Command:

$EB

n Asynchronous Word Length

Values:

n = 0 or 1

Default:

0

Description:

$EB0 Enables 10-bit mode.
$EB1 Enables 11-bit mode.

Command:

$SB

n

Serial Port Baud Rate

Values:

n = speed in bits per second

Default:

57600

Description: $SB300

Set serial port to 300 bps.

$SB1200

Set serial port to 1200 bps.

$SB2400

Set serial port to 2400 bps.

$SB4800

Set serial port to 4800 bps.

$SB9600

Set serial port to 9600 bps.

$SB19200

Set serial port to 19200 bps.

$SB38400

Set serial port to 38400 bps.

$SB57600

Set serial port to 57600 bps.

$SB115200 Set serial port to 115200 bps.

Command: +DCS=

x,y Select V.44 Data Compression

Values:

x = 0 or 1 (V.42bis)
y = 0, 1, or 2 (V.44)

Default:

1, 2

Description:

Selects V.42bis/V.44 data compression.

+DCS=0,0 V.42bis and V.44 data compression are both disabled.
+DCS=0,1 V.42bis is disabled; V.44 data compression is acceptable.
+DCS=0,2 V.42bis is disabled; V.44 only when connected to a V.92

server.

+DCS=1,0 V.42bis is acceptable; V.44 data compression is disabled.
+DCS=1,1 V.42bis is acceptable; V.44 data compression is acceptable.
+DCS=1,2 V.42bis is acceptable; V.44 only when connected to a V.92 server.
+DCS=?

Displays the allowed values.

+DCS?

Displays the current value.