ELECTRICAL HOOKUP (FIGURE 22)

1. If you have an optional temperature gauge to monitor

heat exchanger temperature in your comfort control

center, then the thermocouple wires must be connected

to the gauge when installing the control. See figure 20.

IMPORTANT: Remove the wire ground clip from the ter-

minals of the gauge and connect White wire to + termi-

nal and Red wire to - terminal. See figure 22.

2. A prewired conduit is connected to the comfort con-

trol center for the circulating blower. The opposite end is

to be connected in the junction box on the blower motor.

Connect like colored wires. Secure conduit to junction

box with box connector.

3. The comfort control is factory wired to the forced draft

motor (optional on Model 526). If you have the forced

draft, locate a wall thermostat in the desired location of

you house and run #18 thermostat wire (not furnished)

from this thermostat to R and G terminals of the trans-

former in the comfort control. These connections have

been routed to a terminal strip on the outside of the

comfort control box for convenient connection.

4. The circulating blower limit control is factory wired to

the comfort control center. Jumper removed, normal fan

limit control settings are 160°F ON, and 110°F OFF.

5. Route 110VAC power through conduit from your

power supply to the comfort control center box. Route

through box connector provided and connect hot (L

1

) to

BLACK, Neutral to WHITE and ground to GREEN as

shown on figure 22. You must provide a power discon-

nect in the power supply line to your furnace which is

within sight of the Woodchuck and not more than 30

feet away. Your circuit breaker at the power supply may

meet these requirements.

SLIDE FLANGES OF

CIRCULATING BLOWER

BEHIND ANGLES ON BACK

OF FURNACE

ELECTRICAL

CONNECTION BOX

FORCE FLANGE OF SUPPORT

ANGLE INTO GROOVE ON FURNACE

MOUNTING STRIP

ACCESS DOOR

HOLE FOR

CONDUIT

FILTER (NOT

SUPPLIED)

FILTER

ANGLES

BEND TABS ON SUPPORT ANGLE

OVER, BEHIND FLANGE ON FILTER

BOX, TOP & BOTTOM

SUPPORT ANGLE

GROOVE IN

FURNACE

MOUNTING STRIP,

BOTH SIDES

FIGURE 21 INSTALL CIRCULATING BLOWER AND FILTER