Operating your woodchuck furnace, Burning wood in your wood- chuck, Startup – Meyer WOODCHUCK 526 User Manual

Page 9

Advertising
background image

9

OPERATING YOUR WOODCHUCK

FURNACE

STARTUP

Never leave ash pan in unit. Use only when cleaning

out ashes.

First thing is to check that your main blower and draft

blower are in proper working order before lighting a fire.

To check main blower, push button on fan/limit control

for manual override testing. When finished, reset to au-

tomatic position, figure 5. Next, turn thermostat upstairs

to high temperature so draft blower turns on.

NOTE: All models are equipped with a “low limit” which

will not allow the auto draft to operate when the unit is

not warm. To start auto draft, turn Lo-Limit toggle switch

on comfort control center to “On”, figure 6.

Now you are ready to light a fire.

BURNING WOOD IN YOUR WOOD-

CHUCK

1. Adjust draft channel selector, figure 5, to appropriate

fuel setting on model 2900/4000. On Model 526 with

manual draft, open it. Place several pieces of crumpled

paper in the center of your Woodchuck. Criss-cross a

couple of handfuls of dry kindling wood 3/4" thickness,

then several small dry pieces of firewood. Ignite the pa-

per and close the door. Do not attempt to open the door

immediately after igniting the fire. There could be a

flame flash out.

2. It will take 5-10 minutes for the fire to establish itself.

Once you have some good red hot burning embers,

add larger pieces of wood. All chimneys and hookups

are different. After 3-4 fires, you’ll find out how your unit

works for the best starting.

3. After about 30-40 minutes you can adjust the draft

according to your needs. Adjust smoke pipe damper ac-

cording to your needs also.

NOTE: On airtight units, the burning time is controlled

mostly by the draft controls on the furnace, contrary to

FIGURE 6 COMFORT CONTROL CENTER

CIRCULATING

BLOWER

DRAFT BLOWER

LO-LIMIT BYPASS

DRAFT BLOWER

MANUAL SWITCH

COMFORT

CONTROL CENTER

DOUBLE LATCH

LOADING DOOR

SHAKER

GRATE

FORCED DRAFT

BLOWER

ASH DOOR

DRAFT CHANNEL

SELECTOR - 80/20

COMBUSTION AIR

RATIO CONTROL

MODELS

2900/4000

FAN/LIMIT

HEAT EXCHANGER

CONTROL ROD

COMFORT

CONTROL CENTER

DOUBLE LATCH

LOADING DOOR

MANUAL DRAFT

(Forced Draft Is

Optional)

ASH DOOR

SHAKER GRATE CRANK.

SHAKER GRATES ARE OPTIONAL

MODEL 526

FAN/LIMIT

FIGURE 5 WOODCHUCK CONTROLS

Advertising