8

Appendix

8.1

AT Commands MIM-G01

This chapter describes the most important MIM-G01 AT modem commands. Detailed informa-
tion on these may be obtained from

www.mitsubishi-automation.de.

8.1.1

Important AT Commands

+CPIN – PIN

This command requests the PIN status and enters the PIN/PUK.

Defined parameters:
<pin>

4...8 digit PIN

<puk>

8 digit PUK

+CSQ – Signal Quality

This Command requests the signal quality.

Defined parameters:
<rssi> :

<ber> :

0: -113 dBm or less

0…7: RXQUAL value

1: -111 dBm

99: unknown or not recognizable

30: -109 ... -53 dBm
31: -51dBm or more
99: unknown or not recognizable

Appendix

AT Commands MIM-G01

Mitsubishi Industrial Modem

8 - 1

Command

Possible answers

AT+CPIN?

+CPIN: READY PIN

OK or not necessary

+CPIN: SIM PIN

PIN required

+CPIN: SIM PUK

PUK1 required

+CPIN: SIM PIN2

PIN2 required

+CPIN: SIM PUK2

PUK2 required

+CME ERROR: <err>

SIM error

AT+CPIN=<pin>

Note: enter PIN

OK

AT+CPIN=<puk>,<pin>

Note: enter PUK and new PIN

OK

Tab. 8-1:

+CPIN – PIN

Command

Possible answers

AT+CSQ

+CSQ: <rssi>,<ber>

OK

Note: <rssi> and <ber> see below

Tab. 8-2:

+CSQ – Signal Quality