+ICF – Data Format

This Command sets data format of serial interface.

Defined parameters:
<format>

<parity>

<format>

<parity>

1: 8 Data 2 Stop

0: Odd

4: 7 Data 2 Stop

3: Space

2: 8 Data 1 Parity 1 Stop

1: Even

5: 7 Data 1 Parity 1 Stop 4: None

3: 8 Data 1 Stop

2: Mark

6: 7 Data 1 Stop

If <format> is 1, 3, 4 or 6, <parity> will be ignored

+IFC – Flow Control

This Command determines flow control on serial interface.

Defined parameters:
< DCE_by_DTE >

< DTE_by_DCE >

0: none

0: none

2: RTS

2: CTS

Appendix

AT Commands MIM-G01

Mitsubishi Industrial Modem

8 - 3

Command

Possible answers

AT+ICF?

+ICF: <format>,<parity>

OK

Note: current values

AT+ICF=<format>,<parity>

OK

Tab. 8-6:

+ICF – Data Format

Command

Possible answers

AT+IFC?

+IFF: <DCE_by_DTE>,<DTE_by_DCE>

OK

Note: current values

AT+IFC=<DCE_by_DTE>,<DTE_by_DCE>

OK

Tab. 8-7:

+IFC – Flow Control