6.4.2

TransMode Command

6.4.3

TransMode Login Command

To use the TransMode of the Mitsubishi Super Modem, these prerequisites must be met

b The Mitsubishi Super Modem must be connected to a working telephone connection. That

means you must be able to call it. (check first using a telephone)

b Call answering on the Mitsubishi Super Modem must be activated

(

AT+T Answer="On").

b The Mitsubishi Super Modem must first be configured using the TransMode command.

For access to a PLC connected to a Mitsubishi Super Modem a log in to the Mitsubishi Super
Mode via a modem connection is required. Use a Mitsubishi Super Modem or any other modem
for this purpose.

Send the login command for the TransMode command at the latest five seconds after CON-
NECTING.

There are two possibilities for the login command, which are described as follows.

Configuration

RS 232-Transparent-Mode (TransMode)

Mitsubishi Industrial Modem

6 - 7

AT+T SEND="TransMode; ..."

AT+T SEND="TransMode; Enabled:Enabled;Password: Password; Format: Format;

Handshake:Handshake; Keep:timeout; Baudrate: RS232Speed;
Com:Port"

Switches the RS 232 to a connected device during dial-in from the outside
so that the device can be controlled remotely.

Enabled

Sets theTransMode to active (On) or inactive (Off).

Password

Access password
This protects your Mitsubishi Super Modem AT from unauthorized dial-in
and thus protects the connected control unit from being used by unauthori-
zed persons.
When no password is indicated (default: empty) and AT+T Answer="On",
anything can be selected.

format

Data format of the RS232 interface.
Notation: DatabitsParityStopbits

. Default: 8N1.

handshake

Handshake protocol for the RS 232.
Values: None, RTSCTS, XONXOFF

timeout

Idle timeout - Sets how long the connection remains available in case no
more data is transmitted.
The default value is 75 seconds.
A value of 0 switches this function off, that is, the Mitsubishi Super Modem
will not end the connection even if no more data is coming

RS232Speed

Data speed on the RS 232
between the Mitsubishi Super Modem and device connected to it.
Default value: 115,200 Baud.

Port

Remote interface to connect to.

Example:

The Mitsubishi Super Modem is configured for the TransMode:

AT+T SEND="TransMode; Password:sesam; Format:8N1; Handshake:None;

Keep:20; Baudrate:9600; Enabled:On; Com:MB"

When a call is being received, the Tixi modem connects the RS 232 to the connected device.
All data is now transmitted in both directions as if the devices were connected directly.