Miller Electric 500DX R User Manual

Page 13

Advertising
background image

OM-129 647 Page 9

SECTION 2 − DEFINITIONS

2-1. Symbols And Definitions

Stop Engine

Start Engine

Ether Starting Aid

Engine

Do Not Switch

While Welding

Battery (Engine)

Circuit Breaker

Engine Oil

Check Injectors/

Pump

Check Valve

Clearance

Fuel

Protective Earth

(Ground)

Positive

Negative

Certified/Trained

Mechanic

Welding Arc

A

Amperes

V

Volts

Panel/Local

14

Remote

On

Temperature

Output

Alternating

Current

Stick (SMAW)

Welding

Constant Current

(CC)

MIG (GMAW)

Welding

Constant Voltage

(CV)

Time

h

Hours

s

Seconds

1

Single Phase

3

Three Phase

Read Operator’s

Manual

SECTION 3 − SPECIFICATIONS

3-1. Weld, Power, And Engine Specifications

Welding

Mode

Weld

Output

Range

Rated Welding

Output

Maximum

Open-

Circuit

Voltage

Auxiliary Power

Rating

Engine

Fuel Capacity

CC/DC

45 − 600 A

500 A, 40 Volts DC,

60% Duty Cycle

95 (88 in CC

mode on

units with CV)

Single-Phase,

3 kVA/kW, 25 A,

Deutz F3L-912

Air-Cooled,

Three-Cylinder,

23 gal (87 L)

CV/DC

(Optional)

14 − 38 V

400 A, 36 Volts DC,

100% Duty Cycle

48

3 kVA/kW, 25 A,

120 V AC, 60 Hz

Three Cylinder,

41.5 HP Diesel

Engine

23 gal (87 L)

Advertising