OM-129 647 Page 34

7-9. Inspecting And Cleaning Optional Spark Arrestor Muffler

ST-800 633-B / Ref. ST-180 933-B

Y Stop engine and let cool.
1

Spark Arrestor Muffler

2

Cleanout Plug

Remove plug and remove any dirt

covering cleanout hole.
3

Exhaust Pipe

Start engine and run at idle speed

to blow out cleanout hole. If nothing

blows out of hole, briefly cover end

of exhaust pipe with fireproof

material.
Y Stop engine and let cool.
Reinstall cleanout plug.

Tools Needed:

3

2

1

3/8 in

7-10. Overload Protection For Models With CV Option

1

Circuit Breaker CB3

CB3 protects the 115 volt ac output

to Remote receptacle RC3 and ter-

minal strip 2T.
If CB3 opens, the 115 volt ac output

stops.
2

Circuit Breaker CB4

CB4 protects the 24 volts ac output

to Remote receptacle RC3 and ter-

minal strip 2T.
If CB3 opens, the 24 volt ac output

stops.

.

Press button to reset circuit
breaker. If a breaker continues

to open, contact Factory Au-

thorized Service Agent.

1

ST-800 862-A / ST-148 404

2

Advertising