OM-129 647 Page 27

SECTION 7 − MAINTENANCE & TROUBLESHOOTING

7-1. Routine Maintenance

Follow the storage procedure in the engine owner’s manual if the unit will not be

used for an extended period.

NOTE

Recycle

engine

fluids.

Y Stop engine before maintaining.

.

See also Engine Manual and Maintenance Label.
Service engine more often if used in severe

conditions.

*

To be done by Factory Authorized Service Agent.

8 h

Check Fluid

Levels. See

Section 4-5.

Wipe

Up

Spills.

Drain Water

From Fuel

System.

OIL

Full

FUEL

WATER

50 h

Clean Air Filter.

See Section 7-3.

Clean And

Tighten

Weld

Terminals.

100 h

Clean And

Tighten

Battery

Connections.

Change Oil. See

Section 7-4.

Change Oil

Filter. See

Section 7-4.

250 h

200 h

Check And

Clean Spark

Arrestor. See

Section 7-9.

Replace

Unreadable

Labels.

500 h

Repair

Or

Replace

Cracked

Cables.

1000 h

Blow Out Or

Vacuum Inside.

During Heavy

Service,

Clean Monthly.

OR

Drain Sludge

From Fuel

Tank. See

Section 7-4.

FUEL

SLUDGE

Service Welding

Generator Brushes

And Slip Rings.

Service More Often

In Dirty Conditions.*

Change Fuel

Filters. See

Section 7-4.

Check

Valve

Clearance.*

1/2 in.

(13 mm)

Check Belt

Tension. See

Section 7-7.