11. terminal strip 2t connections (optional) – Miller Electric 500DX R User Manual

Page 23

Advertising
background image

OM-129 647 Page 19

4-10. Remote 14 Receptacle RC3 Information (Optional)

Socket*

Socket Information

A

J

B

K

I

A

24 volts ac. Protected by circuit

breaker CB4.

B

I

C L N

H

D M

G

B

Contact closure to A completes 24

volts ac contactor control circuit.

D M

G

E

F

I

115 volts ac. Protected by circuit

breaker CB3.

J

Contact closure to I completes 115

volts ac contactor control circuit.

OR

G

Circuit common for 24 and 115

volts ac circuits.

OR

C

0 to +10 volts dc output to remote

control from min to max of Amper-

age/Voltage control R1.

A/V

D

Remote control circuit common.

Ref. ST-800 862-B

A/V

E

0 to +10 volts dc input command

signal from remote control.

Ref. ST 800 862 B

K

Chassis common.

*The remaining sockets are not used.

4-11. Terminal Strip 2T Connections (Optional)

Ref. ST-800 862-B / Ref. ST-185 316

Y Stop engine.
If remote control plug does not fit in

receptacle RC3, wire cord directly

to terminal strip 2T.
Y Do not connect to Remote

14 receptacle RC3 and ter-

minal strip 2T at the same

time. Use only one remote

control method.

Open right side door.
1

Cover

2

Terminal Strip 2T

Connect leads to 2T using terminal

information shown in Section 4-10.
Reinstall cover. Close door.

Tools Needed:

1

2

Advertising
This manual is related to the following products: