OM-129 647 Page 21

5-2. Description Of Standard Controls (See Section 5-1)

.

This unit has a max OCV control circuit
that resets the Amperage/Voltage Con-

trol to maximum when the arc breaks.

When an arc is struck, weld output con-

trol returns to the front panel or remote

control setting. The Amperage/voltage

Control adjusts amperage only when

welding and does not adjust open-circuit

voltage.

1

Ampere Range Switch

Use switch to select one of five ampere

ranges.
For most welding applications, use lowest

amperage range possible to help prevent arc

outages.
Y Do not switch under load.
2

Amperage/Voltage Control

Control adjusts amperage within range se-

lected by Ampere Range switch. Weld output

would be 223 A DC with controls set as

shown (50% of 125 to 320 A).
3

Remote A/V Control Receptacle And

Switch

Connect optional remote control to RC3 (See

Section 4-9). Use switch to select front panel

or remote amperage control (see example

below).
4

Manual Stop Control

5

Engine Start Button

6

Ether Starting Aid Switch (Optional)

Push switch up and release while cranking

engine to release ether.
Y Do not use Ether if engine is running.

To Start: Press button and use Ether switch

(if necessary). Release button when engine

starts.

Do not crank engine while engine is turning.

To Stop: Pull control out and hold. Release

control when engine stops.

7

DC Ammeter (Optional)

8

DC Voltmeter (Optional)

9

Oil Pressure Warning Light

Light goes off if oil pressure is too low.

Y If light goes off, stop engine and

check oil level.

10 Battery Charging Warning Light

Light goes on when battery is not charging.

Y If light goes on, stop engine and

check engine belt.

11 Engine Hour Meter

12 Polarity Switch (Optional)

S-0774 / Ref. ST-180 933-B

Example: Combination Remote Amperage Control

In Example:

Range = 125 to 320 A

Percentage Of Range = 50%

Max = 223 A DC (50% of 125 to 320)

Adjust Optional Remote Control

Set Switches

Set Range

Set Percentage

Max (223 A DC)

Min (100 A DC)

Advertising