Chapter 7 Wiring Diagrams and Signal Information

7-395

Signal line name

Description

TONER FULL SENSED(H)+3.3VDC

Waste toner recovery bottle full detection signal by SENSOR
TONER FULL

ADC VOUT

Measured data (analog value) by ADC Sensor in SENSOR ADC
ASSY

ADC MONITOR

Monitor output signal by ADC Sensor in SENSOR ADC ASSY

GLED

LED control signal (analog value) in SENSOR ADC ASSY

ENV HUMI

Environment temperature data (analog value) measured by
SENSOR HUM TEMP

ENV TEMP

Environment temperature data (analog value) measured by
SENSOR HUM TEMP