FIP-26 Black Toner Empty (Black Toner Low)

Step

Check

Yes

No

1

Initial check
Check the following for damage.

SENSOR TONER LOW condition
TONER CARTRIDGE condition
TONER MOTOR condition

Replace the parts
concerned

Go to step [2]

2

Check TONER CARTRIDGE
Check if an error occurs though the TONER CARTRIDGE
was the replaced with a new one.

Go to step [3]

End of work

3

Check PWBA HNB DRV for signal
Is P/J51-36PIN <=> P/J51-35PIN less than +0.2VDC?

Go to step [6]

Go to step [4]

4

Check HARNESS ASSY TNR for continuity
J444 <=> J51 check continuous?

Go to step [5]

Replace
HARNESS ASSY
TNR

5

Check SENSOR TONER LOW
Check if an error occurs though the SENSOR TONER LOW
was replaced with a new one.

Go to step [6]

End of work

6

Check HARNESS ASSY DRV2 for continuity
J12-24 <=> J42-7 check continuous?

With tool
Go to step [7]
Without tool
Go to step [8]

Replace
HARNESS ASSY
DRV2

7

Check TONER MOTOR
Does TONER MOTOR function normally?
Using TONER MOTOR diagnostic tool, check by Diagnostic
Output Test.
In the test, close the INTERLOCK SW.

Check the toner
stirring AUGER or
gear for damage

Go to step [8]

8

Check PWBA DRV3 for signal
Is P/J51-24PIN <=> P/J60-2PIN +24VDC?

Go to step [9]

Replace PWBA
HNB DRV

9

Check HARNESS ASSY TNR for continuity
J514 <=> J51 check continuous?

Go to step [10]

Replace
HARNESS ASSY
TNR

10

Check TONER MOTOR
Check if an error occurs though the TONER MOTOR was
replaced with a new one.

Go to step [11]

End of work

11

Check HARNESS ASSY DRV1 for continuity
Check the following for continuity.
J11-37 <=> J41-4
J11-38 <=> J41-3
J11-39 <=> J41-2
J11-40 <=> J41-1

Replace PWBA
HNB DRV, and if
still faulty, replace
PWBA HNB MCU

Replace
HARNESS ASSY
DRV1