FIP-P3 Black Prints

Condition / initial check

∆ The entire image area is black.

▼ Initial check ▼

Incorrect parts, improper installation, damage, deformation, dirt, foreign substance attached, etc.
∇ Major parts to be checked ∇

Imaging Unit (PHD), Transfer Unit (BTR), ROS ASSY, PWBA HNB MCU

Item

Check

Remedy

1

Faulty transfer
Is the image quality improved if the laser beam exit
window of ROS ASSY is shielded with a sheet?

Replace the PWBA HNB MCU

2

Faulty ROS ASSY
Is the image quality improved if ROS ASSY is replaced?

Replace the ROS ASSY

3

Faulty Imaging Unit (PHD)
Is the image quality improved if Imaging Unit (PHD) is
replaced?

Replace the Imaging Unit (PHD)