3400724000

page 6

Run Time Chart for Various Loads

25% Load

50% Load

75% Load

100% Load

Model

500

35

15

8

4

650

45

19

12

7

800

35

16

8

4

1200

35

15

8

4

Product Specifications

500

650 / 800

1200

UPS VA rating:

480 (4 A)

650 / 800 (5.7 / 6.7 A)

1200 (10 A)

UPS W rating:

285

420 / 520

780

Surge suppressor

720 (6 A)

VA rating:
Input/Output voltage:

106/120/127 VAC*

106/120/127 VAC*

106/120/127 VAC*

50/60 Hz

50/60 Hz

50/60 Hz

Boost mode

input voltage

84 to 96 V

84 to 96 V

84 to 96 V

output voltage

97 to 110 V

97 to 110 V

97 to 110 V

Deep discharge

4 hrs. max

4 hrs. max

4 hrs. max

protection:

run time

run time

run time

UPS back-up time:

4 minutes

7/4 minutes

4 minutes

UPS output wave shape: Modified sine

Modified sine

Modified sine

Load shedding

3 grouped

3 grouped

receptacles:
Surge suppressor

185

185

185

joule rating:
Input cord:

6 foot with rotating

6 foot with rotating

6 foot with rotating

NEMA 5-15 plug

NEMA 5-15 plug

NEMA 5-15 plug

Circuit breaker:

15 amp

15 amp

15 amp

Agency approvals:

UL, cUL, FCC

UL, cUL, FCC

UL, cUL, FCC

Recharge time:

8 hours

8 hours

8 hours

Battery:

1 each 12 volt, 5 Ah

2 each 12 volt, 5 Ah

3 each 12 volt, 5 Ah

Battery life:

3 years

3 years

3 years

UPS current limit:

>100% Load

>100% Load

>100% Load

Operating temperature:

0-35 C/32-96 F

0-35 C/32-96 F

0-35 C/32-96 F

Storage temperature:

0-50 C/32-122 F

0-50 C/32-122 F

0-50 C/32-122 F

Size:

12" X 12" X 3.2"

13" X 13" X 5"

13" X 13" X 5"

Weight:

15 lbs.

21 lbs.

26 lbs.

Warranty:

2 years

2 years

2 years

parts and labor

parts and labor

parts and labor

Accessories:

6' fax/modem cable,

6' fax/modem cable,

6' fax/modem cable,

communication cable

communication cable

communication cable

(RS232 or USB)

(RS232 or USB)

(RS232 or USB)

* Input voltage and transfer voltage to battery is user selectable. Go to UPS Manager/UPS Driver in

Solution Pac software to adjust.

Performance & Product Specifications

E N G L I S H

MGE UPS Systems

Ellipse Premium User’s Manual

page 5

Substituição de Baterias

P O R T U G U Ê S

Modelo 650/800

!

C

Red

Blk.

1

2

Vermelho

Preto

!

C

Red

Blk.

1

2

Red

3

Model 1200

Vermelho

Preto

Vermelho

Advertising