page 20 —gb2000 balloon lighT• operaTion and parTs manual — rev. #3 (08/30/12)

type 1 setup (s/n G1900118 and belOw)

preparaTion

1. Place the light tower in an area free of dirt and debris

with enough clearance as not to interfere with any

overhead obstructions. Make sure it is on secure level

ground with chock blocks underneath each wheel to

prevent the light tower from rolling.

2. If the light tower is in the deployed position, place the

tower mast into the cradle support (stowed position).

See Figure 5. Make sure cradle lock/release pin has

been inserted and the mast is locked.

Figure 5. Light Tower in Stowed Position

disassembly

1. For LT12D light towers, disconnect the negative cable

(black) from battery. See Figure 6.

Figure 6. Disconnecting Battery

danger

alWays make sure the area above

light tower is open and clear of

overhead power lines and other

obstructions. The tower extends in

excess of 30 ft. (9 meters). Contact

with overhead power lines or other

obstructions could result in equipment

damage, serious injury or death!

STOWED POSITION

MAST LOCK

DISCONNECT

NEGATIVE

BATTERY CABLE

2. For MLT series light towers disconnect the 4-pin power

cable (Figure 7) from the 125 VAC twist-lock receptacle

on the front panel of the generator.

Figure 7. MLT Power Cable Removal

3. Disconnect the lamp power cables from receptacles

J1 thru J4 on the T-Bar assembly. See Figure 8.

Figure 8. Remove Cables

4. Remove all 4 lamps (Figure 9) from the T-Bar by

removing the bolts (with washers and nuts) securing

each lamp to the T-Bar.

5. Keep the removed lamps and the associated hardware

together and store in a safe place, making sure that

the lamps are properly protected to prevent breakage.

IDLE CONTROL

0

0

0

0

0

HOURS

ON

OFF

WHISPERW

ATT

7KW AC
Model DA-7000S

S

7000 WATT

DIESEL POW

ERED AC GEN

ERATOR

STARTER SWITCH

RUN

HEAT

START

STOP

HOUR METER

AC VOLTMET

ER

AC CIRCUIT

BREAKER

120/240V

25A

25A

120V

20A

25A

MLT

LIGHT TOWER

TO BALLAST

COMPARTMENT

4-PIN POWER

CABLE

DISCONNECT

J1

J2

J3

J4

UNPLUG THE

CABLES FROM THE

RECEPTACLES

Advertising