OperatiOn

inFlaTing balloon and Turning on lamps

mlT only

1. On MLT series light towers, reconnect the 4-pin power

cable (Figure 31) to the 120 VAC twist-lock receptacle

on the front panel of the generator.

Figure 31. MLT Ballast 4-pin

Power Cable

2. Slightly raise the light tower mast to allow clearance

for the balloon to inflate.

3. Start the light tower engine as referenced in the MLT

operation manual.

4. Once, the engine has started, place the GFCI and main

circuit breaker switches (Figure 32) on the MLT front

control panel in the

on position. The balloon should

begin to inflate.

Figure 32. Main, GFCI Circuit Breakers (ON/MLT)

IDLE CONTROL

0

0

0

0

0

HOURS

ON

OFF

WHISPERW

ATT

7KW AC
Model DA-700

0SS

7000 WATT

DIESEL POW

ERED AC GEN

ERATOR

STARTER SWITCH

RUN

HEAT

START

STOP

HOUR METER

AC VOLTMET

ER

AC CIRCUIT

BREAKER

120/240V

25A

25A

120V

20A

25A

TO BALLAST

COMPARTMENT

4-PIN POWER

CABLE

MLT LIGHT TOWER

IDLE CONTROL

0

0

0

0

0

HOURS

ON

OFF

WHISPERW

ATT

7KW AC
Model DA-7000S

S

7000 WATT

DIESEL POW

ERED AC GEN

ERATOR

STARTER SWITCH

RUN

HEAT

START

STOP

HOUR METER

AC VOLTMET

ER

AC CIRCUIT

BREAKER

120/240V

25A

25A

120V

20A

25A

TO BALLAST

COMPARTMENT

4-PIN POWER

CABLE

MAIN CIRCUIT

BREAKER

(

)

ON

GFCI CIRCUIT

BREAKER

(

)

ON

MLT LIGHT TOWER

5. Next, turn on lamp circuit breakers as referenced in the

lamp lighting options section of this manual.

6. Secure any unused lamp cables.
7. Raise the light tower mast (Figure 30) to the desired

upright height.

deFlaTing and sToring balloon

1. Turn lamps

oFF and allow to cool for at least five

minutes.

2. Once the lamps have cooled, place the GFCI and main

breaker switches in the

oFF position.

3. Unplug power cord from the GFCI receptacle on the

generator.

4. When the balloon is completely deflated, unzip the

protective cover and fold the balloon inside the cover.

5. Carefully zip up the cover and snap the buttons to fully

close the protective cover.

6. Remove all cables from T-Bar, and remove balloon

power cable from junction box.

7. Pull cotter pin from locking pin and remove lamp

assembly from light tower mast.

8. Store lamp assembly in a safe place where it will not

get damaged.

NOTICE

alWays make sure lamps are turned off and allowed

to cool before deflating balloon to avoid any damage

to the balloon.

never transport GB2000 lamp fixture

while attached to mast.