PAGE 20 — ST4125G/ST6125G SUBMERSIBLE PUMP • OPERATION MANUAL — REV. #0 (11/18/10)

Pump Placement

1. Attach a suitable lifting chain to the eye bolts (Figure 10)

on the pump. Use a crane, or similar lifting device and
lower the pump into place. For applications where there
is an excessive amount of mud, grit or silt, the use of
a support platform is desirable.

Figure 10. Placing the Submersible Pump

(Correct Upright Position)

LIFTING

CHAIN

4 or 6-INCH

DISCHARGE

HOSE

POWER

CORD

SUPPORT

PLATFORM

CONNECT

TO CONTROL

BOX

LOWER

2. Make sure the pump is always placed in an upright

position, not tilted (Figure 11). Never position the pump
directly on a soft, loose bottom. To attain maximum
pumping capacity and prevent excessive wear, position
the pump so it will not burrow itself into sand or clay.

Figure 11. Tilted Position (Incorrect)

Control Box Operation (Manual Mode)