Cb12/cb14 control box wiring diagram, Cb-12, Cb-14 – Multiquip Submersible Pump ST4125G User Manual

Page 26: Three phase wiring connections

Advertising
background image

PAGE 26 — ST4125G/ST6125G SUBMERSIBLE PUMP • OPERATION MANUAL — REV. #0 (11/18/10)

CB12/CB14 CONTROL BOX WIRING DIAGRAM

L1

THREE PHASE WIRING

CONNECTIONS

EXTERNAL 3-PHASE

(230 OR 460 VOLT)

POWER SOURCE

CIRCUIT

BREAKER

RED

WHITE

BLACK

L1

L2

L3

GREEN

GROUND

G

ON

INDICATOR

LAMP

M

A1

A2

4

3

2

3

4

1

STOP

FLOAT

SWITCH

START

FLOAT

SWITCH

TERMINAL

BLOCK

CONTACTOR

5 HP

L2

L3

PUMP

MOTOR

T1

T2
T3

O/L

M

CB-12/CB-14

POWER

INPUT

L1

L2

L3

GRN

BLK

H3

H2

H1

H4

50VA CPT

CONTROL

TRANSFORMER

X1

X2

F1

FUSE

1/2 AMP

XF

1

BLK

OFF

4

MAN

AUTO

2

NO

WHT AWG 10

X2

NC

OVERLOAD

RELAY

SEE TABLE 2

FOR CORRECT

HEATER SELECTION

O/L

WHT

GRN

RED AWG 8

RED AWG 8

RED AWG 8

WHT

AWG 10

RED

AWG 10

RED

AWG 10

RED

AWG 10

FUSE

X2

XF

X1

H4

H2

H3

H1

110

115

120

X1

TRANSFORMER

SELECTABLE 230 OR 460 VAC

VOLTAGE INPUTS

H1

H3

H2

H4

230V INPUT

L1

L2

JUMPER

TAB

H1

H3

H2 H4

CB-12

460V INPUT

L1

L2

CB-14

RED

WHT

Figure 21. CB12/CB14 Control Box Wiring Diagram