ENVIROMENTAL SPECIFICATIONS

Operating Temperature Range

-30

°C / +60°C

Storage Temperature Range

-40

°C / +85°C

Humidity

% 95, 50

°C

ESD

IEC 801- 2KV

Water and Dust Protection

IP65, MIL-STD


MILITARY STANDARDS 810C/D/E/F

MIL-STD 810C

MIL-STD 810D

MIL-STD 810E

MIL-STD 810F

Method

Proc./

Cat.

Method

Proc./

Cat.

Method

Proc./

Cat.

Method

Proc./

Cat.

Low Pressure

500.1 I 500.2 II 500.3 II 500.4 II

High Temperature

501.1 I,

II 501.2

I/A1,
II/A1

501.3

I/A1,
II/A1

501.4

I/Hot,
II/Hot

Low Temperature

502.1 I 502.2

I/C1,
II/C2

502.3

I/C1,
II/C2

502.4

I/C1,
II/C2

Temperature
Shock

503.1 – 503.2

I/A1-C2

503.3

I/A1-C2

503.4

I/Hot-C2

Solar Radiation

505.1 II 505.2 I 505.3 I 505.4 I

Rain

506.1 I,

II 506.2 I,

II 506.3 I,

II 506.4 I,

III

Humidity

507.1 II 507.2 II 507.3 II 507.4 –

Salt Fog

509.1 – 509.2 – 509.3 – 509.4 –

Sand and Dust

510.1

I

510.2

I, II

510.3

I, II

510.4

I, II

Vibration

514.2

VIII/F,

XI/H

514.3 I/10, II/3 514.4 I/10, II/3 514.5 I/24, II/5

Shock

516.2

I, II

516.3

I, IV

516.4

I, IV

516.5

I, IV