Chapter ii heater installation – Mr. Heater MH25LP User Manual

Page 5

Advertising
background image

E5

Installation instructions and Owner’s Manual

Model # MH25NG/LP

HS25NG/LP

CHAPTER II

HEATER INSTALLATION

1. GENERAL INSTALLATION INFORMATION

AND REQUIREMENTS

• The required minimum clearances to combustible

surfaces are illustrated in Figure 2 and Table 3.

As shown on Figure 2, the front of the heater is

installed at the minimum required clearance to

combustible surfaces and toward open space,

and then the other sides must have a minimum

clearance of 16 inches to combustible surfaces.

EXHAUST

VENT

CEILING

14”

MINIMUM

16”

MINIMUM

48”

MINIMUM

OPEN

WORKSHOP DOOR

HEATER

WALL BRACK-

ET

16”

MINIMUM

14-1/2”

FLOOR LINE

30

1.

ONLY FLUE SIDE OF HEATER CAN

BE ELEVATED (30

o

).

2.

HEATER SIDE REFLECTOR MUST

BE HORIZONTAL.

NOTE:

Figure 2. Installation Clearances to Combustible Surfaces

Table 3. Installation, Ventilation and Mounting Information

BTU/HR. RATING

NORMAL

MODEL

GAS

MOUNTING

CLEARANCES TO COMBUSTIBLE SURFACES

NO.

NAT.

L.P.

POSITION

TOP

SIDES

BACK

BELOW

MH/HS25NG 25,000 —

30

o

14”

16”

16”

48”

MH/HS25LP

22,000

30

o

14”

16”

16”

48”

Advertising