Installation instructions and Owner’s Manual

Model # MH25NG/LP

HS25NG/LP

This heater may be mounted on any wall;

however, it is recommended that the heater be

mounted in the middle of the wall opposite any

overhead doors.

When selecting installation locations for this

heater ensure that the opening of any exterior

or interior doors or windows will not violate

minimum clearances or contact any heater

components.

If an overhead door is installed in the build-

ing, verify that the heater is not installed in

such a way as to interfere with door operation

and verify that the door in its open position

will not reduce clearances below the minimum

requirements. Never mount the heater in such

a way that would position the heater above an

opened overhead door.

In most cases the infiltration around your unin-

sulated entry doors and windows will provide

enough air flow for efficient heater operation.

Unrestricted air flow during heater operation is essen-

tial to prevent the area above the installed heater from

overheating. If your workshop/utility building is tightly

insulated (including windows, doors, openings, etc.) the

following ventilating methods must be followed:

A single exhaust vent is supplied with your

heater for your convenience. This vent must

be located above the heater (preferably at the

highest point in the building interior) and it must

vent to the exterior of the building. An addition-

al vent is available from the factory for those

having a finished workshop or utility building.

An intake vent, or equivalent, from the exterior

of the building and having an effective area of

75 square inches must be located below the

heater (preferably within 2 feet of the building’s

floor).

Openings equivalent to intake vent would be:

partially open doors and partially open win-

dows.

Openings of this size (5 inch by 13 inch, or 3

inch by 25 inch) will prevent dangerous heat

buildup above the heater.

Ensure that no gas lines or electrical wiring or conduits

will interfere with mounting of the heater to the wall.

Depending on local codes and requirements and the

installer’s skill level, the sizing and installation of gas

lines required to supply the heater may require the

assistance of a professional. If in doubt as to these

requirements, discuss the requirements of this manual

with the dealer from whom the heater was purchased

and your gas supplier, or call our customer service

department at 1-800-251-0001.

The selection of the thermostat mounting location is

critical to efficient and effective heater operation.

The thermostat should be mounted about 5 feet

above the floor where air can circulate freely

around it.

The thermostat should not be mounted directly

to a cold exterior wall without an insulated

mounting block.

The thermostat should not be mounted in direct

drafts.

The thermostat should not be mounted directly

below the installed the heater.

The thermostat should not be installed at a

distance that is farther from the heater than the

length of the thermostat cable.

2. HEATER MOUNTING INSTRUCTIONS

After selecting the heater installation location and the

thermostat location and after verifying and ensuring that

all of the above placement requirements are fulfilled,

mount the heater as follows:

A. Determine how you wish to install the vent based

on the construction of the building and your

personal preference. (i.e., do you wish the flanged

(finished) side on the interior or the exterior of the

building or do you want two vents so that both

exterior and interior will be finished?) If needed,

order an additional vent from the factory. Our

address and toll free phone number are on the rear

cover of this manual. Install the vent as follows:
1. See Figure 3 for dimensions and information on

the vent.

2. Select a place as high above the heater as

possible in accordance with the above require-

ments and ensure that the vent or vents will

not contact or interfere with existing building

systems (i.e., ducts, wiring, plumbing, etc.)

3. Place the unfinished side of the vent against

the wall in its elected location and trace its

dimensions on the wall with a pencil or other

suitable marker.

4. Cut or otherwise open a hole in the wall, or

walls for finished buildings, having the dimen-

sions of the unfinished side of the vent.

5. Install the vent or vents as desired and retain