E9

Installation instructions and Owner’s Manual

Model # MH25NG/LP

HS25NG/LP

quirements and piping requirements are fulfilled, install

piping as follows:
A. In accordance with the above piping requirements,

assemble piping, sediment trap, shutoff valve, and

necessary fittings. Tighten all components securely.

WARNING: Failure to ensure that male threads on

pipe to be installed into gas valve meet the require-

ments of Figure 6 may cause gas valve damage,

distortion and malfunction.

B. Install a threaded nipple, prepared in accordance

with paragraph 3.2 into gas valve.

C. Connect gas piping to nipple installed in the gas

valve.

SUPPLY

LINE

SHUTOFF

VALVE

1/2”

TEE

3”

CAP

NIPPLE

HEATER

RIGID PIPE WITH

UNION OR A FLEXIBLE CON-

NECTOR TO HEATER

Figure 7. Typical Piping Installation

NOTE:
1. ONLY USE A PIPE COMPOUND

WHICH IS RESISTANT TO

LIQUIFIED GASES ON LP

INSTALLATIONS.

2. FITTINGS SHOWN ARE NOT

INCLUDED WITH HEATER.

WARNING: When testing gas piping use only a

soap and water solution. Do not use a match or

other flame for leak testing. If during leakage check

gas is smelled, turn off the gas supply and ventilate

building.

D. Ensure the building is properly ventilated. Without

lighting the pilot light of the heater, open the gas

supply valve and pressurize the piping up to the

heater’s gas valve.

E. Using a brush, apply a soap and water solution to

all connections and look for bubbles indicating a

leak. If a leak is detected, turn off gas supply and

tighten connections. Retest and tighten connections

Advertising