Engine crank detection programming explanations, Engine crank detection programming, 3x 9x + 1x (hold) – Magnadyne Extreme Series X9 User Manual

Page 23: Step 1 step 2

Advertising
background image

23

Engine Crank Detection Programming Explanations

Use the transmitter buttons as illustrated to adjust the features required. Keep re-pressing the transmitter button that
relates to the feature you want to adjust until the correct amount of chirp/beeps is heard. Move on to the next feature.

In this programming group you will set the type of engine starting detection you want to use in your installation.
There are 3 types available:

1. Tachometer (RPM) Detection: (Most reliable and recommended) This type of detection requires a wire

connection to the vehicles ignition coil. You must also “teach” the remote start unit the engine idle RPM level
before you can start the engine by remote.

2. Voltage Detection: This method detects the drop and rise in the battery voltage when the vehicle is started by

remote. This type of detection requires a solid main power input connection but it does not require any
additional hard wire connections.

Enter the crank detection programming mode, select the engine checking type, then follow the procedures to test
and re-set the cranking perimeters as needed.
Note: The default detection setting is “Voltage Detection”. Once your wiring is completed, you can press the

button (2) times and start the engine to make sure all your connections are good to this point.

With the ignition switch in the OFF position, turn the
ignition switch On - Off - On - Off - On - Off.

Before 15 seconds has passed, push and release the
valet switch 10 times holding the button down on the
10th press. Wait for 5 short chirps/beeps + 1 long
chirp/beep. Release the button. You are now in “Engine
Crank Detection Programming” mode.

Engine Crank Detection Programming

ON

ON

3X

9X + 1X (Hold)

Step 1

Step 2

One Chirp

Two Chirps

Three Chirps

Four Chirps

Button

LED One Pulse

LED Two Pulse

LED Three Pulse

LED Four Pulse

(Factory Default Setting)

Exit the Programming Mode (3 long chirps and 3 parking light flashes to confirm this exit)

Tachometer

Checking Type

RPM Learning Start
Timer:
0.6 second (1 chirp)

0.8 second (2 chirps)
1.0 second (3 chirps)
1.2 second (4 chirps)

1.4 second (5 chirps)
1.6 second (6 chirps)
1.8 second (7 chirps)

2.0 second (8 chirps)
3.0 second (9 chirps)
4.0 second (10 chirps)

Voltage Checking

Type

Fixed Crank

Mode

+

Hi Check Level

Low Check Level

Start/Stop the System for Testing and Adjustment

-

Shock Sensor Test

Mode is Off

-

Shock Sensor Test

Mode is On

Advertising