2-8. Slope Selection (250 Ampere Model)

Ref. ST-801 518-A

Y Disconnect and lockout/tag-

out input power before re-

moving side panel.

Lockout/tagging procedures con-

sist of padlocking line disconnect

switch in open position, removing

fuses from fuse box, or shutting off

and red-tagging circuit breaker or

other disconnecting device.
1

Slope Connection Label

2

Tapped Reactor AC-Z And

Slope Coils

Tapped reactor AC-Z is factory con-

nected to slope tap 8 which is suit-

able for most GMAW applications.
AC-Z controls the inductance

applied to the weld current. To

increase inductance and wet out

the weld puddle, connect to a higher

tap number. To stiffen the weld

puddle, connect to a lower tap num-

ber.
3

Leads 70, 71 and 72 With

Pressure Connectors

Slide pressure connectors onto the

same tap of each coil, and secure

them.
Y An unbalanced secondary

current can damage the main

transformer and cause errat-

ic weld conditions. Be sure

leads 70, 71 and 72 are con-

nected to the same

numbered slope turn tap on

each coil. See slope

connection label .

4

Firing Board PC1

5

Receptacle RC2

6

Lead 36

7

Receptacles RC3 Through

RC6

Connect lead 36 from RC2 to

correct receptacle RC4, RC5, RC6

or RC7 to match tap slope connec-

tions made in Section A as follows:
RC3 − 300A (Used With 300A Mod-

els Only)
RC4 for 4 turns
RC5 for 6 turns
RC6 for 8 turns
RC7 for 10 turns.
Reinstall right side panel.

1

2

3

1/2 in
3/8 in

4

7

5

6

S-177 763-B

8 6 4

8 6 4

8 6 4

0

0

0

SLOPE TURNS

TAP SLOPE CONNECTIONS

IMPORTANT:

Be sure connections are clean

before reconnecting tap.

IMPORTANT:

Move friction lug on PC1 to

correct tab to insure proper

operation of voltmeter preset.

10

10

10