15. connecting input power, Important – Miller Electric CP-252TS User Manual

Page 23

Advertising
background image

OM-259 Page 19

2-15. Connecting Input Power

ST-800 103-B / Ref. ST-801 116

Y Disconnect and lockout/tagout input

power before connecting input con-

ductors from unit.

Y Have only qualified persons make this

installation.

See rating label on unit and check input volt-

age available at site.
1

Line Disconnect Device

2

Input Conductors

3

Grounding Conductor

Select size and length using Section 2-13.

Conductors must comply with national, state,

and local electrical codes. Use lugs of proper

amperage capacity and correct hole size.

4

Strain Relief

Route conductors through strain relief.
5

Machine Grounding Terminal

6

Line Terminals

Y Make input power connections to the

welding power source before making

connections into a deenergized line

disconnect device.

Connect green or green/yellow grounding con-

ductor to machine grounding terminal first.

Then connect input conductors to line termi-

nals.
Close access door.
7

Disconnect Device (Supply) Grounding

Terminal

8

Disconnect Device Line Terminals

Y In the deenergized line disconnect de-

vice, connect green or green/yellow

grounding conductor to supply

grounding terminal first, never to a line

terminal. Be sure grounding conductor

goes to an earth ground.

Connect input conductors to line terminals.
9

Overcurrent Protection

Select type and size using Section 2-13 (fused

disconnect switch shown).
Close door on line disconnect device.

3/8 in, 1/2 in

= GND/PE Earth Ground

Tools Needed:

When making connections in

the line disconnect device,

connect the Green Or

Green/Yellow conductor first.

Install conductors into

a deenergized line

disconnect device.

Make connections

to machine first and

supply last.

IMPORTANT

GND/ PE Connect Green Or Green/Yellow

GND/PE Conductor First.

L1

L2

L3

L1 (U)

L2 (V)

L3 (W)

2

6

3

5

.

Tighten nuts to 65 in lb +/- 5 in lb.

4

1

9

8

3

7

3/8 in, 1/2 in

Advertising