11. remote 14 receptacle information – Miller Electric CP-252TS User Manual

Page 20

Advertising
background image

OM-259 Page 16

2-10. Weld Output Terminals And Selecting Cable Sizes

Y ARC WELDING can cause Electromagnetic Interference.
To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.

Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed

and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving

the welding machine, using shielded cables, using line filters, or shielding the work area.

Total Cable (Copper) Length In Weld Circuit Not Exceeding

100 ft (30 m) Or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Connecting to weld

output terminals

Welding

Amperes

10 − 60%

Duty

Cycle

60 − 100%

Duty

Cycle

10 − 100% Duty Cycle

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

+

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

400

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

500

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-3/0

*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for

the mm

2

equivalent weld cable sizes.

S-0007-E

2-11. Remote 14 Receptacle Information

Socket*

Socket Information

A

24 volts ac. Protected by circuit breaker CB2.

B

Contact closure to A completes 24 volts ac contactor control circuit.

I

115 volts, 15 amperes, 60 Hz ac. Protected by circuit breaker CB1.

J

Contact closure to I completes 115 volts ac contactor control circuit.

A

J

B

K

I

C L N

H

G

Circuit common for 24 and 115 volts ac circuits.

C L N

H

D M

G

E

F

K

Chassis common.

*The remaining sockets are not used.