2. overload protection – Miller Electric CP-252TS User Manual

Page 25

Advertising
background image

OM-259 Page 21

4-2. Overload Protection

Y Disconnect and lockout/tagout

input power before removing

side panel.

Lockout/tagging procedures consist of

padlocking line disconnect switch in

open position, removing fuses from fuse

box, or shutting off and red-tagging cir-

cuit breaker or other disconnecting de-

vice.
1

Fuse Panel Module

Fuses F1 and F2 protect transformer

T1.
If one fuse link opens, low weld output is

available at output terminals.
If both fuse links open, no weld output

will be available at the output terminals.

.

Incorrect fuse can damage unit.

Use only replacement fuse of same

size, type and rating (see Section 6).
Replacing Fuse(s)
Remove top and right side panels.
Replace open or damaged fuse(s).
Reinstall side and top panels.

803 492-A

3/8 in
1/2 in

1

.

Tighten nuts to 65 in lb
+/- 5 in lb.