OM-259 Page 17

2-12. Connecting To 115 Volts AC Duplex Receptacle

Ref. ST-801 380-B

1

115 V 15 A AC Receptacle

RC9

Power is shared between RC9 and

remote 14 receptacle RC8.
2

Circuit Breaker CB1

3

Circuit Breaker CB2

CB1 protects 115 volts ac portion of

RC8 and RC9 from overload.
CB2 protects 24 volts ac portion of

RC8 from overload.
Press button to reset breaker.

1

3

2

2-13. Electrical Service Guide

60 Hertz Models

250 Amp Model

300 Amp Model

Input Voltage

200

230

460

200

230

460

575

Input Amperes At Rated Output

34.5

30

15

38

33

16.5

13

Max Recommended Standard Fuse Rating In Am-

peres

1

Time-Delay

2

40

35

15

45

40

20

15

Normal Operating 3

50

45

20

60

50

25

20

Min Input Conductor Size In AWG/Kcmil

8

10

14

8

8

12

14

Max Recommended Input Conductor Length In Feet

(Meters)

116 (35)

100 (31) 157 (48)

105 (32) 139 (42)

221 (67) 223 (68)

Min Grounding Conductor Size In AWG/Kcmil

10

10

14

10

10

12

14

Reference: 1999 National Electrical Code (NEC)

1 Consult factory for circuit breaker applications.
2 “Time-Delay” fuses are UL class “RK5” .

3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and

above).

50 Hertz Models

300 Amp Model

Input Voltage

220

380

400

440

520

Input Amperes At Rated Output

34.5

20

19

17.3

14.6

Max Recommended Standard Fuse Rating In Amperes

1

Time-Delay

2

40

25

20

20

15

Normal Operating 3

50

30

30

25

20

Min Input Conductor Size In AWG/Kcmil

8

12

12

12

14

Max Recommended Input Conductor Length In Feet (Meters)

127

(39)

151

(46)

167

(51)

202

(62)

183

(56)

Min Grounding Conductor Size In AWG/Kcmil

10

12

12

12

14

Reference: 1999 National Electrical Code (NEC)

1 Consult factory for circuit breaker applications.
2 “Time-Delay” fuses are UL class “RK5” .

3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and

above).