Section 8 − operating optional battery charger, 1. battery charge controls, 2. determining battery charging current – Miller Electric 250 User Manual

Page 31

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-217 455 Page 27

SECTION 8 − OPERATING OPTIONAL BATTERY CHARGER

8-1. Battery Charge Controls

!

Have only qualified persons charge

batteries.

!

Do not use battery charger for jump

starting.

NOTICE − D o not use generator power ac re-

ceptacles while using optional battery charger.

Low voltage at receptacles may damage tools

and other equipment.
1

Charge Voltage Switch

Place switch in position matching voltage of

battery being charged.

.

Before connecting charging cables, place
Charge Voltage switch in position match-

ing voltage of battery being charged.

2

Battery Charging Switch

Place switch in On position to turn on charging

current. Place switch in Off position to turn off

charging current.
3

Weld Process Switch

!

Place switch in Charge position before

connecting charging cables and start-

ing engine.

Use switch to select weld or battery charge

output (see table in Section 8-2).
4

Coarse Range Switch

5

Fine Control

Use Coarse Range switch and Fine Control to

set charge current.

!

Do not change Coarse Range or Weld

Process switch position while welding

or battery charging.

.

Charging current automatically stops
when terminal voltage is 15 to 25 percent

above required battery voltage.

1

3

5

4

2

228 649-A

8-2. Determining Battery Charging Current

1

Battery Charging Current Chart

Find battery cold crank amp (CCA) rating on

battery. Use CCA rating on chart to find charge

current setting for battery.
EXAMPLE: If battery CCA rating is 500, charg-

ing current from chart is 100 amperes.
Do not exceed charging current found on

chart. For longer battery life, use lowest

charge rate possible.

1

0

50

100

150

200

250

300

350

400

0

500

1000

1500

2000

BA

TTER

Y CHARGING CURRENT (AMPS)

BATTERY COLD CRANK AMP RATING (CCA)

142 975-B

Advertising