OM-217 455 Page 34

9-3. Servicing Air Cleaner

aircleaner1 9/02− ST-153 929-B / ST-153 585 / Ref. S-0698-B

!

Stop engine.

NOTICE − Do not run engine without air

cleaner or with dirty element. Engine

damage caused by using a damaged ele-

ment is not covered by the warranty.

.

The air cleaner primary element can

be cleaned but the dirt holding capac-

ity of the filter is reduced with each

cleaning. The chance of dirt reaching

the clean side of the filter while clean-

ing and the possibility of filter damage

makes cleaning a risk. Consider the

risk of unwarrantable equipment

damage when determining whether

to clean or replace the primary ele-

ment.

If you decide to clean the primary ele-

ment, we strongly recommend instal-

ling an optional safety element to pro-

vide additional engine protection.

Never clean a safety element. Re-

place the safety element after servic-

ing the primary element three times.

1

Intake Manifold

2

Service Indicator (Optional)

3

Window

4

Reset Button

Service air cleaner element if red band

appears in window. A green band means

air cleaner is okay. Press button to reset

indicator.
Clean or replace primary element if dirty

(see note above before cleaning). Re-

place primary element if damaged. Re-

place primary element yearly or after six

cleanings.
5

Housing

6

Safety Element (Optional)

7

Primary Element

8

Cover

9

Dust Ejector

To clean air filter:
Wipe off cover and housing. Remove

cover and dump out dust. Remove ele-

ment(s). Wipe dust from inside cover and

housing with damp cloth. Reinstall safety

element (if present). Reinstall cover.
NOTICE − Do not clean housing with air

hose.
Clean primary element with compressed

air only.
Air pressure must not exceed 100 psi

(690 kPa). Use 1/8 in (3 mm) nozzle and

keep nozzle at least 2 in (51 mm) from

inside of element. Replace primary ele-

ment if it has holes or damaged gaskets.
Reinstall primary element and cover

(dust ejector down).

Blow

Inspect

8

5

7

9

Keep nozzle

2 in (51 mm)

from element.

6

Optional

2

3

4

1