Section 13 − performance data, 1. fuel consumption curves – Miller Electric 250 User Manual

Page 51

Advertising
background image

OM-217 455 Page 47

SECTION 13 − PERFORMANCE DATA

13-1. Fuel Consumption Curves

226795-A / 226 796-A

Auxiliary Power Fuel Consumption

Weld Fuel Consumption

DC WELD AMPERES AT 100% DUTY CYCLE

US Gal./Hr

.

IDLE

0

50

100

150

200

250

300

350

400

0.00

0.25

0.50

0.75

1.00

1.25

1.50

1.75

2.00

AUXILARY POWER KW AT 100% DUTY CYCLE

US Gal./Hr

.

IDLE

0.00

0.25

0.50

0.75

1.00

1.25

1.50

1.75

2.00

0

1

2

3

4

5

6

7

8

9

10

On a typical job using 1/8 in 7018

electrodes (125 amps, 20% duty

cycle), expect about 24 hours of op-

eration.
Welding at 150 amps at 40% duty

cycle uses approximately 1/2 gal-

lon per hour, or about 20 hours of

operation.