4. battery charging procedure – Miller Electric 250 User Manual

Page 33

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-217 455 Page 29

8-4. Battery Charging Procedure

Stop Engine.

Connect Cables (Observe

Correct Polarity).

Turn Off Battery Charging

Switch.

Set Charge Voltage Switch To

Voltage Of Battery Being

Charged (12, 24, Or 36 Volt).

NOTICE − Do not switch under load.

+

Start Engine.

Set Weld Process Switch To

Charge Position.

In Example:

Battery Voltage = 12 Volts

Battery CCA Rating = 500

Charge Current = 100 A (See Section 8-2)

Coarse Range Setting = 60 to 140 A

V/A Control Setting = 50%

Charge 10 minutes.

Check Battery Voltage.

Continue Charging If

Necessary.

Turn On Battery

Charging Switch.

Determine Charge Current From

Battery CCA Rating And Chart

(See Section 8-2).

Set Coarse Range Switch And

Fine Control To Obtain Correct

Charging Current.

NOTICE − Do not switch under load.

Stop Engine.

Charge 10

Minutes