Control panel – Ingersoll-Rand 7120 User Manual

Page 25

Advertising
background image

22

7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)

8

4

9

10

11

12

1

3

5

13

6

7

14

Control Panel

2

DIAGNOSTIC/AUTO SHUTDOWN (STANDARD)

1. Compressor fault – Needs attention. See Wedge
diagnostic panel for more detail.

2. Engine Fault – Needs attention. See Wedge diagnostic
panel for more detail.

3. Hourmeter – Records running time for maintenance.

4. Compressor Discharge Pressure Gauge – Indicates
pressure in receiver tank, psi (kPa).

5. Fuel Level Gauge – Indicates amount of fuel in tank.

CONTROLS (STANDARD)

6. Power Switch – Flip “ON” to activate systems prior to
Starting. Flip “OFF” to stop engine.

7. Service Air Switch – After warm–up, PUSH. Provides full
air pressure at the service outlet.

OPTIONAL CONTROLS

8. Engine Speed Gauge – Indicates engine speed.

9. Discharge Air Temp. Gauge – Indicates in

_

F and

_

C.

Normal operating range: 185

_

F/85

_

C to 248

_

F /120

_

C.

10.Engine Oil Pressure Gauge – Indicates engine oil pressure
(psi (kPa).

11. Engine Water Temp Gauge – Indicates coolant
temperature, with normal operating range from 180

_

F/82

_

C to

210

_

F /99

_

C.

12.Voltmeter – Indicates battery condition.

13.Spare

14.Wait To Start Lamp.