Options – Ingersoll-Rand 7120 User Manual

Page 70

Advertising
background image

OPTIONS

7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),

7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)

67

OPTIONS – Lubricator

(For units manufactured in North America)

SAFETY

WARNING: Ensure that the lubricator filler cap is
re–tightened correctly after replenishing with oil.

WARNING: Do not replenish the lubricator oil, or service
the lubricator without first making sure that the machine is
stopped and the system has been completely relieved of all
air pressure (Refer to STOPPING THE UNIT
in the
OPERATING INSTRUCTIONS
section of this manual).

CAUTION: If the nylon tubes to the lubricator are disconnected
then ensure that each tube is re–connected in its original
location.

GENERAL INFORMATION

Oil capacity:
1 QT Option –0.95 Litre (1qt)
2 QT Option –1.9 Litre (2qts)

Oil specification:
Refer to the Tool Manufacturer’s Manual.

OPERATING INSTRUCTIONS

COMMISSIONING

Check the lubricator oil level and fill as necessary.

PRIOR TO STARTING

Check the lubricator oil level and replenish as necessary.

MAINTENANCE

Check the lubricator oil level and replenish as necessary.

FAULT FINDING

FAULT

CAUSE

REMEDY

No oil flow.

Incorrect connection.

Reverse the nylon
tube connections to
the lubricator.

Advertising