24

7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)

Wedge Diagnostic Display Codes

If the

fault indicator lamp is illuminated, refer to the

Alert/Shutdown list below.

If the

fault indicator lamp is illuminated, refer to the

Engine diagnostic list below.

ALERT/SHUTDOWN CONDITIONS Version: 1.40

Alert

Shutdown

Condition

Code

Light (Blinks)

Code

Light (Steady)

Delay
(sec.)

Engine Speed <900 RPM

1

CPRSR Malf.

30

Engine Speed >2500 RPM

2

CPRSR Malf.

30

Engine Crank Time Exceeded

3

CPRSR Malf.

0

Intake Manifold Temperature > 180
deg. F

6

CPRSR Malf.

Engine Not Responding To Throttle
Command

10

CPRSR Malf.

Engine Shut Itself Down: reason
unknown

29

CPRSR Malf.

Disch. Temp (RT2)
Sensor Fault

32

CPRSR Malf.

10

Sep. Tank Pressure (PT1)
Sensor Fault

33

CPRSR Malf.

Separator Tank Temp.> 247 deg.F)

50

CPRSR Malf.

3

Machine ID Not Valid

51

CPRSR Malf.

0

Sep. Tank Temp. (RT1) Sensor Fault

53

CPRSR Malf.

10

Reg. System Pressure (PT2) Sensor
Fault

54

CPRSR Malf.

Serial Comm. Problem

70

CPRSR Malf.

CAN Bus Problem

71

CPRSR Malf.