OPERATION DESCRIPTION

SETS WITH VARIABLE-SPEED MOTORS AND PRESSURE TRANSDUCER CONTROL

The starting and stopping of the pumps are determined based on the pressure values set on the controller.
Each frequency converter is connected to a pressure transducer.
The controllers exchange information with each other and provide for cyclic changeover.

The figure shows the operating mode of a two-pump booster set
(Typical Field Set).
• On demand, water is drawn from the tank.

• When the pressure drops belows the PS setting the first pump

starts and the speed is adjusted to maintain a costant pressure as
demand increases.

• If the water consumption increases and the pump reaches

maximum speed, the second pump starts and the speed is adjusted
to maintain constant pressure.

• When demand decreases, the speed is reduced until minimum

speed is reached and one of the pumps are switched off.

• If consumption keeps decreasing the pump slows down, fills the

tank and stops at the pressure setting.

PS

Pressure

Flow

Figure 3

Pmax

Duplex

OPERATING CHARACTERISTICS AND LIMITS

Type of pumped liquids

Water containing no gas or corrosive and/or aggressive substances

Fluid temperature

Above 0° F to 180° F, Pressure transducer limited

Ambient temperature

Above 0° F to 104° F, VFD/Display, keep away from direct sun

Maximum operating pressure

360 PSI (Pump without transducer)

Minimum inlet pressure

According to NPSH curve and losses, with a minimum margin of 0.5 m

Maximum inlet pressure

The inlet pressure added to the pressure of the pump at zero flow must be lower

than the maximum operating pressure of the set (suction and discharge).

Installation

Indoors/outdoors, protected from the direct sun. Away from heat sources. Maximum

elevation 3300 feet ASL. Maximum humidity 50% without condensation.

Hourly starts

Maximum 60 up to 10 HP. Above 10 HP and up to 50 HP, maximum 40 starts per

hour. Variable speed drive starts.

Sound emission

See table

* Note: For higher temperature it is necessary to use special materials (only on request).

NOISE EMISSION LEVELS

60 Hz 3500 RPM

LpA (dB ±4)

HP

NEMA Motor Frame

PHV

1

56

< 70

2

56

< 70

3

56

< 70

5

145

< 70

182-184

< 70

10

215

< 70

15

254

73

20

256

75

25

284

75

30

284

75

* Note: Adjusted from 50 Hz data, may vary.