Technical data – pump hydraulics / motor sizing – ITT BPHV User Manual

Page 39

Advertising
background image

39

TECHNICAL DATA – PUMP HYDRAULICS / MOTOR SIZING

46SV 3500 RPM

# of Impellers / Maximum Motor HP for use Motor HP for use Shutoff Shutoff Casing / Sleeve Stages requiring Pump Flange

# reduced

HP

with 1.15 SF

with Hydrovar

TDH

TDH

Pressure rating Thrust Balancing

Rating

Diameter

Draw

Motor

(1.0 SF)

(Feet)

(Bar) (Standard Assy.)

Piston

10/2

77.8

1210

36.1

9

73.2

75

1137

33.9

9/1

71.5

1111

33.2

9/2

69.7

75

1085

32.4

8

65

1010

30.2

8/1

63.3

60

984

29.4

8/2

61.6

959

28.6

40 Bar (580 PSI)

7

56.9

884

26.4

7/1

55.2

60

858

25.6

7/2

53.4

50

832

24.8

Thrust Piston

Class 250 / 300

6

48.8

758

22.6

Required

6/1

47.1

50

732

21.9

6/2

45.3

706

21.1

5

40.7

40

632

18.9

5/1

38.9

40

605

18.1

5/2

37.2

580

17.3

4

32.5

505

15.1

4/1

30.8

30

30

479

14.3

4/2

29

453

13.5

3

24.4

25

379

11.3

25 Bar (362 PSI)

3/1

22.7

20

25

353

10.5

1

3/2

20.9

327

9.8

2

16.3

20

253

7.6

Class 125 / 150

2/1

14/5

15

15

226

6.7

2/2

12.8

200

6.0

1

8.5

10

10

127

3.8

1/1

6.7

7.5

7.5

102

3.0

66SV 3500 RPM

# of Impellers / Maximum Motor HP for use Motor HP for use Shutoff Shutoff Casing / Sleeve Stages requiring Pump Flange

# reduced

HP

with 1.15 SF

with Hydrovar

TDH

TDH

Pressure rating Thrust Balancing

Rating

Diameter

Draw

Motor

(1.0 SF)

(Feet)

(Bar) (Standard Assy.)

Piston

6

73.2

850

25.4

6/1

70.2

75

75

822

24.5

40 Bar (580 PSI)

6/2

67.2

796

23.8

5

61

60

707

21.1

5/1

58

60

681

20.3

Thrust Piston

Class 250 / 300

5/2

55

655

19.6

Required

4

48.8

50

566

16.9

4/1

45.8

50

540

16.1

4/2

42.8

40

513

15.3

3

36.6

40

424

12.7

25 Bar (362 PSI)

3/1

33.6

30

398

11.9

1

3/2

30.6

30

372

11.1

2

24.4

25

25

283

8.4

Class 125 / 150

2/1

21.4

20

257

7.7

2/2

18.4

20

230

6.9

1

12.2

15

15

142

4.2

1/1

9.2

10

10

115

3.4

1 Pump assembly may be modified for 40 bar (580 psi) application – contact factory.