3500 RPM, 60 Hz

HP Phase Enclosure

Nameplate

NEMA

Goulds

FLA

SFA

LRA

S.F.

Efficiency Insulation

Voltage

Frame

PN

¹

Class

1

3

TEFC

230/460

56C

V06742

3.7-3.6/1.8

3.99-3.8/1.9

11

1.25

75.5

B

Prem. Eff. TEFC

230/460

56C

V06742PE

2.8/1.4

3.12/1.56

12.1

1.25

84.5

B

3

TEFC

230/460

56C

V07742

4.9-4.6/2.3

5.3-5.1/2.54

18.4

1.15

80

B

Prem. Eff. TEFC

230/460

56C

V07742PE

4.0/2.0

4.5/2.25

20.1

1.15

85.5

B

2*

3

TEFC

208-230/460

56C

V08742

6.2-5.8/2.9

7.2-6.52/3.26

22

1.15

80

B

Prem. Eff. TEFC 208-230/460

56C

V08742PE

5/4.75-2.5

6.4-5.8/2.9

30

1.15

86.5

B

3*

3

TEFC

208-230/460

56C

V09742

8.1-7.6/3.8

9.5-8.6/4.3

32.9

1.15

82.5

F

Prem. Eff. TEFC 208-230/460

184TC

V09742PE

6.8/3.4

8.5-7.7/3.8

32

1.15

88.5

F

5*

3

TEFC

208-230/460

184TC

V10742A

13.2-12/6

15-13.6/6.8

47

1.15

85.5

F

Prem. Eff. TEFC 208-230/460

184TC

V10742APE

11.2/5.7

14.4-13/6.5

55

1.15

90.2

F

7½*

3

TEFC

208-230/460

184TC

V11742A

18.5/17.4

21.7-19.6/9.8

94

1.15

88.5

F

Prem. Eff. TEFC

230/460

213TC V11742APE

17.8/8.9

20.2/10.1

75

1.15

90.2

F

10*

3

TEFC

208-230/460

215TC

V12742

25-24/12

30.5-27.6/13.8 105

1.15

85.5

F

Prem. Eff. TEFC

230/460

215TC

V12742PE

23.8/11.9

27.6/13.8

112

1.15

89.5

F

15*

3

TEFC

208-230/460

254TC

V13742

35/17.5

43-39/19.5

165

1.15

86.5

F

Prem. Eff. TEFC 208-230/460

254TC

V13742PE

34.4/17.2

43.8-39.6/19.8 112

1.15

91.7

F

20

3

TEFC

208-230/460

256TC

V14742

46/23

59.3-53.6/26.8 160

1.15

89.5

F

Prem. Eff. TEFC 208-230/460

256TC

V14742PE

46/23

57.5-52/26

201

1.15

92.4

F

25

3

TEFC

230/460

284TC

V15742

59/29.5

74.8-67.6/33.8 182

1.15

88.5

F

Prem. Eff. TEFC

230/460

284TC

V15742PE

56/28

69.9-63.2/31.6 236

1.15

93

F

30

3

TEFC

230/460

284TC

V16742

68/34

86.7-78.4/39.2 225

1.15

91

F

Prem. Eff. TEFC

230/460

286TC

V16742PE

66/33

83.8-75.8/37.9 281

1.15

93

F

40

3

TEFC

230/460

284TC

V17742

90/45

103.2/51.6

322

1.15

90.2

F

Prem. Eff. TEFC

230/460

324TSC V17742PE

90/45

102.2/51.1

286

1.15

93.6

F

50

3

TEFC

230/460

326TSC

V18742S

112/56

141.8-128.2/64.1 430

1.15

92.4

F

Prem. Eff. TEFC

230/460

326TSC V18742SPE

108/54

124.8/62.4

422

1.15

94.1

F

NOTES:

¹ Locked rotor amps are for high voltage only.

* Currently available on Packaged Hydrovar.
• Motors are suitable for AQUAVAR® Variable Speed Drive.
Above data is for Baldor® TC and TSC frame motors. Specifications subject to change without notice.