Goulds pumps, Phv - packaged hydrovar series, Variable speed performance curves – ITT BPHV User Manual

Page 34

Advertising
background image

34

Goulds Pumps

PHV - Packaged Hydrovar Series

VARIABLE SPEED PERFORMANCE CURVES

33SV VARIABLE SPEED CURVE
SVB CI/316SS

Multi-Stage Pumps

MODEL: 33SVB 3/1 Stage

Hydraulic Data

Maximum Flow

Flow at Duty Point

Maximum TDH

TDH at Duty Point

NPSH

R

225 US GPM

310 feet

0

20

40

[US GPM]

0

[HP]

5

10

15

[FT]

0

[FT]

Fluid: Water, pure

Duty Chart: 3500 RPM

Head

NPSH - values

Shaft power P2

STAGE 3/1

30 Hz

40 Hz

50 Hz

60 Hz

Application Range

30 Hz

40 Hz

50 Hz

60 Hz

STAGE 3/1 (P2)

30 Hz

40 Hz

50 Hz

60 Hz

60

80

20

25

100

30

0

2

20

120

40

60

140

160

180

200

220

STAGE 3/1

80

4

76.7%

76.7%

76.7%

76.7%

100

6

8

120

140

160

180

200

10

12

14

220

240

260

280

300

320

Advertising