6. Jumper Block Settings

The server board has several 2-pin and 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server board. Pin 1 on each jumper block is denoted by an “*” or “▼”.

6.1 Recovery Jumper Blocks

Table 33. Recovery Jumpers (J1D1, J1D2, J1D3)

Jumper Name

Pins

What happens at system reset…

1-2

BMC Firmware Force Update Mode – Disabled (Default)

J1D1: BMC Force
Update

2-3

BMC Firmware Force Update Mode – Enabled

1-2

These pins should have a jumper in place for normal system operation. (Default)

J1D2: Password
Clear

2-3

If these pins are jumpered, administrator and user passwords will be cleared
immediately. These pins should not be jumpered for normal operation.

1-2

These pins should have a jumper in place for normal system operation. (Default)

J1D3: CMOS
Clear

2-3

If these pins are jumpered, the CMOS settings will be cleared immediately. These pins
should not be jumpered for normal operation

TP02080

3

2

Password
Reset

J1D2

J1D3

3

2

Clear
CMOS

BMC Force

Update Mode

3

2

J1D1

Disable

Enable

Figure 17. Recovery Jumper Blocks (J1D1, J1D2, J1D3)