The bi-color System Status LED will operate as follows:

Color

State

Criticality

Description

Off

N/A

Not ready

AC power off

Green /
Amber

Alternating
Blink

Not ready

Pre DC Power On – 15-20 second BMC Initialization when AC is
applied to the server. Control Panel buttons are disabled until BMC
initialization is complete.

Green

Solid on

System OK

System booted and ready.

Green

Blink

Degraded

System degraded

Unable to use all of the installed memory (more than one
DIMM installed).

Correctable errors over a threshold of 10 and migrating to a
spare DIMM (memory sparing). This indicates that the user
no longer has spared DIMMs indicating a redundancy lost
condition. Corresponding DIMM LED should light up.

In mirrored configuration, when memory mirroring takes
place and system loses memory redundancy. This is not
covered by (2).

Redundancy loss such as power-supply or fan. This does
not apply to non-redundant sub-systems.

PCI-e link errors

CPU failure / disabled – if there are two processors and one
of them fails

Fan alarm – Fan failure. Number of operational fans should
be more than minimum number needed to cool the system

Non-critical threshold crossed – Temperature and voltage

Amber

Blink

Non-critical

Non-fatal alarm – system is likely to fail

Critical voltage threshold crossed

VRD hot asserted

Minimum number of fans to cool the system not present or
failed

In non-sparing and non-mirroring mode if the threshold of
ten correctable errors is crossed within the window

Amber

Solid on

Critical, non-
recoverable

Fatal alarm – system has failed or shutdown

DIMM failure when there is one DIMM present, no good
memory present

Run-time memory uncorrectable error in non-redundant
mode

IERR signal asserted

Processor 1 missing

Temperature (CPU ThermTrip, memory TempHi, critical
threshold crossed)

No power good – power fault

Processor configuration error (for instance, processor
stepping mismatch)


7.2.1

System Status LED – BMC Initialization

When the AC power is first applied to the system and 5V-STBY is present, the BMC controller on the
server board requires 15-20 seconds to initialize. During this time, the system status LED will blink,
alternating between amber and green, and the power button functionality of the control panel is disabled
preventing the server from powering up. Once BMC initialization has completed, the status LED will stop
blinking and the power button functionality is restored and can be used to turn on the server.