97

Sensor

Name

Sensor

Number

System

Applica-

bility

Sensor Type

Event /

Reading

Type

Event Offset

Triggers

Criticality

Assert /

De-assert

Readable

Value /

Offsets

Event Data

Rearm

Standby

Proc 1
Thermal
Control

C0h All Temperature

01h

Threshold
01h

[u] [c,nc]

Threshold
defined

As and De Analog

Trig Offset

M

Proc 2
Thermal
Control

C1h All Temperature

01h

Threshold
01h

[u] [c,nc]

Threshold
defined

As and De Analog

Trig Offset

M

Proc 1
VRD Over
Temp

C8h All Temperature

01h

Digital
Discrete
05h

01h – Limit
exceeded

Non-Critical

As and De

Trig Offset

M

Proc 2
VRD Over
Temp

C9h All Temperature

01h

Digital
Discrete
05h

01h – Limit
exceeded

Non-Critical

As and De

Trig Offset

M

Proc 1 Vcc D0h

All

Voltage
02h

Threshold
01h

[u,l] [c,nc]

Threshold
defined

As and De Analog

R, T

A

Proc 2 Vcc D1h

All

Voltage
02h

Threshold
01h

[u,l] [c,nc]

Threshold
defined

As and De Analog

R, T

A

Proc 1 Vcc
Out-of-
Range

D2h All Voltage

02h

Digital
Discrete
05h

01h – Limit
exceeded

Non-Critical

As and De Discrete

R, T

A

Proc 2
Vcc Out-
of-Range

D3h All Voltage

02h

Digital
Discrete
05h

01h – Limit
exceeded

Non-Critical

As and De Discrete

R, T

A

CPU
Population
Error

D8h All Processor

07h

Generic
03h

01h –- State
asserted

Critical

As and De

R, T

A

Fault status
asserted

Degraded

Device installed OK
Disabled Degraded

DIMM A1

E0h

All

Slot
Connector
21h

Sensor
Specific
6Fh

Sparing OK

As –

Trig

Offset

A

DIMM A2

E1h

All

Slot
Connector

Sensor
Specific

Fault status
asserted

Degraded As

– Trig

Offset