Server Board S5000PAL / S5000XAL TPS

Appendix B: Sensor Tables

Revision 1.4

Intel order number: D31979-007

91

Sensor

Name

Sensor

Number

System

Applica-

bility

Sensor Type

Event /

Reading

Type

Event Offset

Triggers

Criticality

Assert /

De-assert

Readable

Value /

Offsets

Event Data

Rearm

Standby

Fan 1
Present

60h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Fan 2
Present

61h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Fan 3
Present

62h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Fan 4
Present

63h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Fan 5
Present

64h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Fan 6
Present

65h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Fan 7
Present

66h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Fan 8
Present

67h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Fan 9
Present

68h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Fan 10
Present

69h Chassis-

specific

Fan
04h

Generic
08h

Device present OK

As and De

T

A

Redundancy
regained

OK

Redundancy
lost
Redundancy
degraded

Degraded

Fan
Redun-
dancy

6Fh Chassis-

specific

Fan
04h

Generic
0Bh

Non-red: suff
res from redund
Non-red: suff
from insuff

OK

As –

Trig