Figure 23. Installing the Memory

6. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the

open position (see letter “A” in the figure above).

7. Holding the DIMM by the edges, remove it from its anti-static package.

8. Position the DIMM above the socket. Align the notch on the bottom edge of the

DIMM with the key in the DIMM socket. The arrow in the inset in

Figure 23

is

pointing to the key in the socket (see letter “B” in the figure above).

9. Insert the bottom edge of the DIMM into the socket.

10. When the DIMM is inserted, push down on the top edge of the DIMM until the

retaining clips snap into place (see letter “C” in the figure above). Make sure the
clips are firmly in place (see letter “D” in the figure above).

TP02072

DIMM A1

Socket

DIMM A2

Socket

DIMM B1

Socket

DIMM B2

Socket

DIMM D2
Socket

DIMM D1
Socket

DIMM C2
Socket

DIMM C1
Socket

A

C

D

B