Ms-dos/windows 3.1x driver installation, Initio, Aspi disk driver command line options – Initio I/O HIGHWAY User Manual

Page 25

Advertising
background image

21

initio

®

ASPI Disk Driver Command Line Options

INIDISK.SYS is a DOS block device driver for supporting SCSI fixed disks, removable

disks and MO devices. INIDISK.SYS is automatically loaded in CONFIG.SYS start up file

by the Initio DOSSETUP or SETUP programs. INIDISK.SYS requires that the Initio ASPI

Manager be loaded. INIDISK.SYS can be loaded with either the DEVICE= or

DEVICEHIGH= command. INICD.SYS can be found on

the INI-9XXXU/9XXXUW DRIVER

DISK 1

. Below is a list of command line options and examples.

/R /r

This option specifies the number of logical drives to reserve for MO and

removable disk devices. MO and removable disks media are capable of being parti-

tioned just like a fixed disk. For every DOS partition on the media a logical DOS drive

letter will be available. INIDISK.SYS will support as many logical drives as required (up to

the maximum supported by DOS) based on the partitioning of the media that is present

when your system boots. However, the media may be removed at any time and a new

disk may be inserted. The new disk may have more (or less) partitions then the original

disk. The /R /r option is used to reserved drive letters at start up in order to facilitate a

disk change to a disk with more partitions than the original disk present at boot time.

The value after the /R /r option determines how many drive letters will be reserved on a

device basis. For example, if the user specifies a /R4 option and there are two removable

devices attached to the SCSI bus, then a total of eight (8) drive letters will be reserved.

/T /t

This option is used to specify a Time out value to be used when sending

commands to a SCSI drive. If a SCSI drive does not respond to a command within the

specified time out then the command will be aborted and an appropriate error message

will be displayed. The time out value is specified in minutes. Valid values are 1-9 and D

or d. The D or d values are used to Disable the time out mechanism. If the time out

mechanism is disabled then faulty hardware can lock up the system.

Examples:

/T4

/Td

/TD
/T1

/X /x

This option is used to exclude particular SCSI drives. Excluded SCSI drives are

identified by specifying the host adapter, target id and lun. These values are spereated

by a colon. Groups of SCSI drives (or wild cards) can also be identified. Below are

examples of the different ways SCSI drives can be excluded:

/X0:1:2

This will exclude the drive on Host Adapter 0, with target ID 1

and lun 2.

/X0:2

This will exclude the drive on Host Adapter 0, with target ID 2

and ANY lun