Quantum Series Installation and Service Manual

- 13 -

720901120

No water dispensed,

concentrate only

(con’t).

Freeze-up of water coil or

concentrate chamber

Unplug dispenser and allow 2-4

hours to thaw. Water or concen-

trate thermostat set too low,

recalibrate to 34

o

F -40

o

F (1.1

o

C - 4.5

o

C).

Defective water or concentrate
thermostat, replace.

Refrigerant solenoid stuck open
or not closing fully. Evacuate
system, replace solenoid valve
and recharge

No water and no con-
centrate, refrigeration is
working

Service switch located

under drip tray in OFF
position

Turn on switch

Door switch open

Door switch must be closed in

order to operate pump. Check
switch operation and replace if
necessary

No water and no con-
centrate, refrigeration is
working

6.25 amp Fuse inside front

electrical box blown

Replace with 6.25 amp, 250VAC

slow blow fuse and test

No output from Transformer

located on rear upper
shelf

Confirm transformer output by

measuring for 26VAC at fuse.
Replace transformer if neces-
sary

Defective voltage regulator

board (VRB) located
inside front electrical
box

Measure across the blue and black

wire located in the upper left
corner of the board. There
should be 28VDC present when
the dispense button is pressed.
Replace VRB if necessary

Defective portion control

board

Disconnect wire harness from rear

of portion control, close door
switch and short the orange
and black wires together on the
harness. If unit dispenses por-
tion control board is defective. If
it does not dispense the voltage
regulator board is defective.