Cornelius QUANTUM SERIES User Manual

Page 20

Advertising
background image

Quantum Series Installation and Service Manual

720901120

-

18 -

Sold Out light illumi-

nates when concen-

trate no longer
passes through the
pump.(con’t)

Improper loading proce-

dures will usually result

in low brix conditions
and thus erratic sold out
indications.

Check that the pouch of juice is

properly loaded in the pouch

holder. Tube fitting should be
located at the bottom of the
pouch holder and the tube
should be approximately cen-
tered in the bottom portion of
the opening of the holder.

Check that the tube is correctly

loaded in the pump and the
pump is fully locked (top and

bottom slide pins should be
fully engaged into the pump
body).

Tube has been stretched

through pump when it

was loaded. Pouch may
not be seated correctly.

Adjust pouch. If pouch is loaded

correctly there should be ample

tube to reach the mixing cham-
bers without stretching the
tube.

Check that the rollers on the

pump are spinning
freely with no tube in
place.

If the rollers are sticky or locked up

see the platform removal and
cleaning procedure.

Sold Out light fails to

reset itself after door

is opened and
closed (Sold Out
light stays illumi-
nated)

Check the operation of the

reset switch located at

the bottom left hand
side of the door.

Adjust Switch.

Advertising