Cornelius QUANTUM SERIES User Manual

Page 17

Advertising
background image

Quantum Series Installation and Service Manual

- 15 -

720901120

Concentrate refill light

does not come on at

all (con’t)

Improperly loaded tube

Refer to concentrate loading sec-

tion of this manual

Bad VRB board

Replace VRB board

Bad portion control

Replace portion control

Warm Drink

Incoming water supply too

warm

Optimum performance is achieved

when the dispenser utilizes
water from a pre-cooler

Ambient air too warm

Relocate dispenser

Excessive demand on dis-

penser

Add water pre-cooler or second

dispenser

Dirty condenser coil

Clean condenser coil

Inoperative condenser fan

Replace condenser fan motor

Defective water thermostat

Replace thermostat

Loss of refrigerant charge

due to leak in system

Repair leak and recharge system

Water continuously drips

from nozzle when in
OFF mode

Main water solenoid at base

of unit or water solenoid
on pump platform not
shutting off tightly

Clean solenoid(s), replace parts as

necessary

No Flush Cycle

Run/Flush switch on pump

platform in Run mode

Move switch to Flush position

Defective Run/Flush switch

on pump platform (con-
centrate continues to
dispense while in Flush
mode)

Replace Run/Flush switch

Concentrate warm,

water cold

Concentrate thermostat is

turned off or not cali-
brated properly

Calibrate to be 34

o

F -40

o

F (1.1

o

C

–4.5

o

C)

Concentrate thermostat
defective (stuck open)

Replace thermostat and calibrate

to 34

o

F -40

o

F (1.1

o

C –4.5

o

C)

Defective start relay located

on upper rear shelf
inside dispenser

There should be line voltage on the

black wire of the relay when
there is line voltage present on
the orange OR yellow wire.
Replace relay if it fails this test.